CiencIPCA >
Instituto Politécnico do Cávado e do Ave >
Escola Superior de Design >
Departamento de Arte e Comunicação >
DAC - Artigos em revistas científicas >

Please use this identifier to cite or link to this item: http://hdl.handle.net/11110/1982

Title: Methodology for Bone–Implant Stiffness Evaluation
Authors: Rosa, Natacha
Tavares, Sérgio
Carbas, Ricardo
Simoes, Ricardo
Magalhães, F.
Marques, António
Keywords: Mechanical experimentation
Issue Date: 2020
Publisher: Experimental Mechanics
Citation: Rosa, N., Tavares, S.M.O., Carbas, R.J.C. et al. Methodology for Bone–Implant Stiffness Evaluation. Exp Mech (2020). https://doi.org/10.1007/s11340-020-00654-w
Abstract: Background It has been difficult to improve the intramedullary nail technique because of the lack of consistency in the procedures used to evaluate the bone-implant stiffness. Objective The goal of this study was to develop a simple methodology for determining the stiffness of a bone implant that considers the physiological loads and bone orientation, and allows a finite element analysis and its validation using mechanical experimentation. Methods Finite element models for a composite tibia before and after an intramedullary nail was implanted were created and validated using the results of a set of mechanical experiments, in which the stiffness values of the model were measured and compared under axial compression, 4-point bending, shear, and torsional loads considering the patient’s condition in the early healing phase. Grips with personalized bone interfaces were developed to guarantee the physiological loads and bone orientation. Results In the 4-point bending, torsional, and shear loading modes, the developed bone-implant finite element model showed a satisfactory level of predictive potential in relation to the experimental observations, with a percentage variation of less than 35%. This study also demonstrated that despite the high stiffness of the bone-implant construct, motion was always generated at the interfragmentary site during the early healing phase. In addition, during this stage, the nail supported most of the load applied to the lower limb (up to 85%). Conclusions This strategy could contribute to the future determination of the ideal mechanical environment at a fracture site and how this environment evolves throughout the healing process.
URI: http://hdl.handle.net/11110/1982
ISSN: 0014-4851
Appears in Collections:DAC - Artigos em revistas científicas

Files in This Item:

File Description SizeFormat
10.1007_s11340-020-00654-w.pdf6.32 MBAdobe PDFView/Open
Restrict Access. You can Request a copy!
Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.